Model | SPR-T200 | SPR-T210 | SPR-I300 | |
Light Source | Type | He-Ne Laser | He-Ne Laser | He-Ne Laser,and LED |
wavelength | 632.8nm | 632.8nm | 632.8nm,and 621±10nm | |
Rotation Stage | Number of Rotation stage | Motor 1, sample motor Motor 2, detector motor |
Motor 1, sample motor Motor 2, detector motor |
Motor 1, sample motor Motor 2, detector motor |
Control of rotation stage | Automatically control | Automatically control | Automatically control | |
Rotation angular resolution | <= 0.02° upgradable |
0.01° upgradable |
0.01° upgradable |
|
Rotation angles | 0-360°(Motor 1) 0-180°(Motor 2) |
0-360°(Motor 1) 0-180°(Motor 2) |
0-360°(Motor 1) 0-180°(Motor 2) |
|
Optimal measurable angles | 15-80°(incident angle) (for prism 1.845) |
15-80°(incident angle) (for prism 1.845) |
15-80°(incident angle) (for prism 1.845) |
|
Anti-collision system | 2 limit switches AZ-721, used to switch off the detector motor when it runs beyond 0-180°. | 2 limit switches AZ-721, used to switch off the detector motor when it runs beyond 0-180°. | 2 limit switches AZ-721, used to switch off the detector motor when it runs beyond 0-180°. | |
Angular calibration | Semi-automatic | Semi-automatic | Semi-automatic | |
Stage | Motion Type | Manual | Manual | Manual |
Translation stage | XYZ mobile platform | XYZ mobile platform | XYZ mobile platform | |
Detector | Photo detector | Photo-diode detector | Photo-diode detector | A photo-diode detector, and a CCD camera |
Flow Cell System | Injection system | Peristaltic Pump | Peristaltic Pump | Peristaltic Pump |
Type | BT100-2J | BT100-2J | BT100-2J | |
Pump channels | 2 | 2 | 2 or 4(Optional) | |
Injection Control | Both Automatic and Manual | Both Automatic and Manual | Both Automatic and Manual | |
Injection Volume | 20-750 μl | 20-750 μl | 20-750 μl | |
Flow Cell Capacity | 20-100 μl | 20-100 μl | 20-100 μl | |
Flow Cell Number | Single Channel | Single Channel | 1-4 Channels (Optional) | |
Basic Parameters | Instrument Size | 1120 mm*560 mm*560 mm | 1120 mm*560 mm*500 mm | 1100 mm*560 mm*500 mm |
Instrument Weight | About 120 kg | About 120 kg | About 120 kg | |
Sensitivity | 10-5-10-6RIU-1 Depends on the sensor chips |
10-5-10-6RIU-1 Depends on the sensor chips |
10-5-10-6RIU-1 Depends on the sensor chips |
|
Accessories | Prism | Refractive index, 1.745 or 1.845 Exchangeable |
Refractive index, 1.745 or 1.845 Exchangeable |
Refractive index, 1.745 or 1.845 Exchangeable |
Flow cell | Quartz and PDMS | Quartz and PDMS | Quartz and PDMS | |
Tubes | 2 Stops, Tygon R3607, ID:0.64mm; Wall:0.91mm |
2 Stops, Tygon R3607, ID:0.64mm; Wall:0.91mm |
2 Stops, Tygon R3607, ID:0.64mm; Wall:0.91mm |
|
Matching Oil | 1.7000±0.0002 Cargille Labs |
1.7000±0.0002 Cargille Labs |
1.7000±0.0002 Cargille Labs |
|
Sample Chips | Sensor chips with 50 nm Au Customizable |
Sensor chips with 50 nm Au Customizable |
Sensor chips with 50 nm Au Customizable |
|
Others | Power Supply | 220V/50 HZ AC | 220V/50 HZ AC | 220V/50 HZ AC |
Software | Sensby SPR | Sensby SPR | Sensby SPR | |
System | Windows 7, 10 | Windows 7, 10 | Windows 7, 10 |
Proteomics | Immunoassay |
Drug Discovery | Vaccine Development |
Cancer Research | Transient Binding |
Cell Signaling | Ligand Fishing |
Multi-molecular Complexes | Binding Specificity |
Molecular Recognition | Structure-function Relationship |
Immune Regulation | Enzyme Reaction |
Model | SPR-T210 | SPR-I400 | |
Detector | Photo detector | Photo-diode detector | CCD |
Flow Cell System | Injection system | Peristaltic Pump | Peristaltic Pump |
Injection Control | Semi-Automatic | Automatic | |
Sampling | -- | 96 hole plate Automatic switching |
|
Injection Volume | 20-750 μl | 20-750 μl | |
Flow Cell Capacity | 20-100 μl | 20-100 μl | |
Flow Cell Number | Single Channel | 4 Channels | |
Basic Parameters | Instrument Size | 1120 mm*560 mm*500 mm | 850 mm*630 mm*611 mm |
Instrument Weight | about 120 kg | about 50 kg | |
Measurable Sample Refractive Index | 1~1.5 | 1~1.5 | |
Sensitivity | ~10-6 RIU Depends on the sensor chips |
~10-6 RIU Depends on the sensor chips |
|
Sensitivity for Concentration Detection | 10 ng/ml | 10 ng/ml | |
Detection Range | 0.1 μg/ml – 5 mg/ml | 0.1 μg/ml – 5 mg/ml | |
Detection Range | 0.05 nM-1 mM | 0.05 nM-1 mM | |
KD Range | 0.05 nM-0.1 mM | 0.05 nM-0.1 mM | |
Accessories | Prism | Refractive index, 1.845 Exchangeable |
Refractive index, 1.845 Exchangeable |
Flow cell | Quartz and PDMS | Quartz and PDMS | |
Tubes | 2 Stops, Tygon R3607, ID:0.64mm; Wall:0.91mm |
2 Stops, Tygon R3607, ID:0.64mm; Wall:0.91mm |
|
Matching Oil | 1.7000±0.0002 Cargille Labs |
1.7000±0.0002 Cargille Labs |
|
Sample Chips | Sensor chips with 50 nm Au Customizable |
Sensor chips with 50 nm Au Customizable |
|
Others | Power Supply | 220V/50 HZ AC | 220V/50 HZ AC |
Software | Sensby SPR | Sensby SPR | |
System | Windows 7, 10 | Windows 7, 10 |